Mixing gas: No mixing gas was used in this run. Typically oxygen is used to maximise the intensities and to minimise the material consumption and carbon contamination.
Microwave power: 350 W
...
Material consumption: The material consumption was not measured in this the experiment resulting in record intensities. Couple of months later the consumption rate of 1 mg/h for the enriched 54Fe was measured. In this experiment the intensity of 52 µA (54Fe11+) was extracted from the JYFL 14 GHz ECRIS. The intensity was not maximised. The main goal was to meet the intensity requirement, with minimum material consumption, and to produce a stable beam. The enriched MIVOC compound (54Fe(C5H5)2) was synthesised at JYFL and used for the experiment.
11+ | 115 |
---|---|
12+ | 101 |
13+ | 58 |
14+ | - |
15+ | 31.2 |
16+ | - |
17+ | 3.2 |
...