Mixing gas: No mixing gas was used in this run. Typically oxygen is used to maximise the intensities and to minimise the material consumption and carbon contamination.

Microwave power: 350 W

...

Material consumption: The material consumption was not measured in this the experiment resulting in record intensities. Couple of months later the consumption rate of 1 mg/h for the enriched 54Fe was measured. In this experiment the intensity of 52 µA (54Fe11+) was extracted from the JYFL 14 GHz ECRIS. The intensity was not maximised. The main goal was to meet the intensity requirement, with minimum material consumption, and to produce a stable beam. The enriched MIVOC compound (54Fe(C5H5)2) was synthesised at JYFL and used for the experiment.

 

11+115
12+101
13+58
14+-
15+31.2
16+-
17+3.2

...