Results with HIISI

Mixing gas: Oxygen

(1)Tuning 4.10.2017

Microwave power: 2000 W + 300 W from 18 GHz + 14 GHz klystrons klystrons

Acceleration voltage : 18 kV/3.6 mA (HIISI extraction system). Plasma electrode aperture 8 mm in diameter.

(2) Tuning 29.5.2018 (test with recently assembled 36 segment hexapole were started)

Microwave power: 2000 W + 500 W from 18 GHz + 14 GHz klystrons 

(3) Tuning 31.5.2018 about 10 % lower B-fields, 1 kW + 0.4 kW µw power

Acceleration voltage 16 kV/4 mA


Material consumption: N/A

Note: Tuning for Ar13+ ion beam.

8+-600 (3)
9+-560 (3)
10+-
11+400620(2)
12+462500 (2)
13+312 312 (1)
14+182 (1)
15+-
1631 (1)

JYFL 14 GHz ECRIS

Mixing gas: Oxygen

...