Acceleration voltage 18 kV/3.6 mA (HIISI extraction system). Plasma electrode aperture 8 mm in diameter.
(2) Tuning 2927.56.2018 (test with recently assembled 36 segment hexapole were started)). Background pressure in injection still quite high (1.5E-7 mbar).
Microwave power: 2000 W + 500 W from 18 GHz + 14 GHz klystrons klystrons. Fast tuning on Ar12+ at 19 kV. Current limit was set to 6 mA. This limit was met and HV automatically shut OFF causing strong spark (destroyed at least puller HV power supply). Intensity gradually increased when Ar feed was increased. I didn't have time to measure Ar13+ but spectrum show that it is about 330 µA or slightly more.
(3) Tuning 31.5.2018 about 10 % lower B-fields, 1 kW + 0.4 kW µw power
...
8+ | 600 (3) |
---|---|
9+ | 560 (3) |
10+ | - |
11+ | 620680(2) |
12+ | 500 560 (2) |
13+ | 312330 (12) |
14+ | 182 (1) |
15+ | - |
16 | 31 (1) |