Mixing gas: Oxygen
(1)Tuning 428.106.2017Microwave power: 2000 W + 300 W from 18 GHz + 14 GHz klystrons2018
Same as (2) with following deviations: BD: -60 V, decreased argon and oxygen feed, decreased current in mid coil, increased injection B-field.
Acceleration voltage 18 kV/3.6 mA (HIISI extraction system). Plasma electrode aperture 8 mm in diameter.
...
Microwave power: 2000 W + 500 W from 18 GHz + 14 GHz klystrons. Fast tuning on Ar12+ at 19 kV. Current limit was set to 6 mA. This limit was met and HV automatically shut OFF causing strong spark (Intensity gradually increased when Ar feed was increased. At the total current of around 6 mA a strong spark appeared which destroyed at least puller HV power supply). Intensity gradually increased when Ar feed was increased. I didn't have time to measure Ar13+ but spectrum show indicates that it is about 330 µA or slightly more.
...
8+ | 600 (3) |
---|---|
9+ | 560 (3) |
10+ | - |
11+ | 680(2) |
12+ | 560 (2) |
13+ | 330 (2) |
14+ | 182 195 (1) |
15+ | - |
16 | 31 (1)130 |
JYFL 14 GHz ECRIS
Mixing gas: Oxygen
...