14 GHz ECRIS, MIVOC method

Titanium beams were produced on JYFL 14 GHz ECRIS using MIVOC method using MIVOC method with commercially available compound (CH3)5C5natTi(CH3)3. The compound is light, air and moisture sensitive. Material Safety Data Sheets for safe use of Ti compound can be found from here.

The source was tuned for Ti11+.

...

Acceleration voltage: 10 kV (JYFL extraction system)

Material consumption: N/A

...

H. Koivisto, J. Ärje, R. Seppälä, and M. Nurmia, Production of Titanium Ion Beams at an ECR ion source, Nucl. Instr. and Meth. in Phys. Res., B187, (2002), p. 111.