14 GHz ECRIS, MIVOC method

Iron beams were produced on JYFL 14 GHz ECRIS using MIVOC method with commercially available compound (CH3)5C5natTi(CH3)3. The compound is light, air and moisture sensitive. 

Note: Afore-mentioned compound is air and light sensitive

Mixing gas: N/A

Microwave power: 350 W 

Acceleration voltage: 10 kV (JYFL extraction system)

Material consumption: N/A

Note: An intensive 50Ti11+ ion beam has been produced by using enriched compound. See the reference shown below (J. Rubert et. al.).

 

8+33
9+43
10+44
11+45 
12+36
13+14.3

 

For more information see:

H. Koivisto, J. Ärje, R. Seppälä, and M. Nurmia, Production of Titanium Ion Beams at an ECR ion source, Nucl. Instr. and Meth. in Phys. Res., B187, (2002), p. 111.

J. Rubert, J. Piot, Z. Asfari, B.JP. Gall, J. Ärje, O. Dorvaux, P.T. Greenlees, H. Koivisto, A. Ouadi, R. Seppäla, First intense isotopic titanium-50 beam using MIVOC method, Nucl. Instrum. and Meth. in Phys. Res. B 276 (2012), p. 33.