Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

Results with HIISI

Mixing gas: Oxygen

(1)Tuning 4.10.2017

Microwave power: 2000 W + 300 W from 18 GHz + 14 GHz klystrons

Acceleration voltage 18 kV/3.6 mA (HIISI extraction system). Plasma electrode aperture 8 mm in diameter.

(2) Tuning 29.5.2018 (test with recently assembled 36 segment hexapole were started)

Microwave power: 2000 W + 500 W from 18 GHz + 14 GHz klystrons 

(3) Tuning 31.5.2018 about 10 % lower B-fields, 1 kW + 0.4 kW µw power

Acceleration voltage 16 kV/4 mA


Material consumption: N/A

Note: Tuning for Ar13+ ion beam.

8+600 (3)
9+560 (3)
10+-
11+620(2)
12+500 (2)
13+312 (1)
14+182 (1)
15+-
1631 (1)

JYFL 14 GHz ECRIS

Mixing gas: Oxygen

Microwave power: 600-800 W

Acceleration voltage: 10 kV (JYFL extraction system)

Material consumption: N/A

TWTA was used for charge states 11-16.

8+359
9+230
10+-
11+142
12+103
13+51 
14+49
15+-
1610